cve
cve

CVE-2021-27196

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...

7.5CVSS

7.4AI Score

0.009EPSS

2021-06-14 10:15 PM
50
2
cve
cve

CVE-2021-35533

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.5CVSS

7.3AI Score

0.001EPSS

2021-11-26 05:15 PM
36
cve
cve

CVE-2022-2502

A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be...

7.5CVSS

7.7AI Score

0.001EPSS

2023-07-26 06:15 AM
19
cve
cve

CVE-2022-28613

A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy RTU50...

7.5CVSS

7.3AI Score

0.001EPSS

2022-05-02 07:15 PM
56
4
cve
cve

CVE-2022-3353

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections. ...

7.5CVSS

7.3AI Score

0.007EPSS

2023-02-21 02:15 PM
30
cve
cve

CVE-2022-4608

A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of se...

7.5CVSS

7.4AI Score

0.001EPSS

2023-07-26 06:15 AM
20
cve
cve

CVE-2023-6711

Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an RTU50...

7.5CVSS

7.6AI Score

0.0005EPSS

2023-12-19 03:15 PM
20